- Home
- 产品线
- Compression Lugs
- Narrow Tongue Lugs
- YAV-L-NTFX | Copper lugs
YAV-L-NTFX | Copper lugs
- General Details
- Features & Benefits
- Related Products
BURNDY® compression lugs are designed for reliable and controllable electrical connections. The complete installation is fully inspectable. They are high conductivity copper and operate cooler than the wire on which they are installed. The connectors withstand a wide range of electrical and environmental conditions, including current surges, temperatures, corrosion and vibrations, for a wide variety of applications. These features mean a consistently high quality connection at a low installed cost.
Copper compression connectors are manufactured from high-conductivity electrolytic copper. The connectors are normally tin-plated, lead plated, or plated with proprietary BURNDY brite finish to provide durable long-lasting corrosion resistance.
The connector design has been matched to the cable size to provide the necessary physical strength requirements for reliable electrical performance.
UL Listed 90° C,600 Volts to 35kV ♦
45° and 90° angles are available.
YAV4CLNT10FX YAV2CLNT14FX YAV2CLNT516FX
YAV25LNT14FX YAV25LNT516FX YAV25LNT38FX
YAV26LNT516FX YAV26LNT38FX YAV26LNT12FX
YAV27LNT12FX YAV28LNT516FX YAV28LNT38FX
YAV28LNT12FX YA30LNT516FX YA31L-NT12-FX
YA32LNT516FX YA32LNT38FX YA38LNT12FX
YA38LNTM20FX YA40LENT12FX YA44LNT38FX
• Inspection window allows for visual verification that the wire has been fully
inserted prior to crimping the lug
• Narrow tongue/tang is designed to allow for parallel terminations of wire in limited
space applications
• Barrel is designed with an internal chamfer at the wire entry to ensure smooth
insertion of the wire, preventing possible damaging of the wire strands during
insertion
• Short/Standard length barrel is recommended for installations with limited space
requirements
• 45º and 90º angular lugs are available; please contact Customer Service
• Electro-tin plated unless otherwise specified to reduce galvanic corrosion
(bimetallic) and resist corrosive elements
• Connectors are clearly marked with stamping and barrel color coding
• Connectors accommodating wire sizes #10 – 4/0 AWG accommodate both Flex
and Code Wire. See Tables on each page for specific details
• Tables in this section identify flex wire as the nominal flex wire size followed by
the wire classes and DLO wire size and stranding. For Class Wire Strand counts,
see the table at the beginning of this section